Smart PDU Power Distribution Unit

A 19-inch rack-mount RV distribution hub: 15 individually controlled DC load channels, built-in coulomb meter for direct energy measurement, integrated water-level, temperature and tire-pressure acquisition, plus centralized charger / inverter management — with a 7-inch touch control panel and offline voice control.

Request a Quote
Smart PDU

Whole-Vehicle Power on One Screen

On top of a conventional distribution box's water-level, temperature and load switching, the Smart PDU integrates energy metering, charge/discharge info, charger & inverter management, tire-pressure monitoring, voice control and operation logs into one 19-inch rack hub.

Distribution Capacity

15 Channels

8×10A + 4×20A + 3×30A — independent per-channel control and status LEDs. One hub manages the whole vehicle's DC loads.

  • 12V system, max charge 50A / discharge 70A
  • Dedicated 30A / 20A / 10A load connectors
  • Blade fuses + per-channel status LEDs, quick replacement from the service port
  • Cable spec: B−/P− 4AWG · B+/30A/20A 8AWG · 10A 10AWG
Built-In Coulomb Meter

0.01V / 0.01A

Energy metering integrated directly in the PDU — no separate shunt meter needed. 1 sample/second with automatic charge/discharge direction detection.

  • Voltage 8–24V / current 0–50A measurement
  • Ah 0–9999.99AH · kWh 0–9999.99kWh
  • Accuracy ±2% (V) / ±5% (A)
  • Five-layer protection: over/under-voltage, over-current, over-power, over-temp
Touch Panel + Voice

7" + Voice Control

The 7-inch TFT touchscreen shows battery state, remaining time, water levels, tire pressure and charging info; an onboard MIC enables offline voice load switching.

  • CAN power & communication, 169×122mm flush cutout
  • Historical data and error logs viewable
  • Voice wake-up + 15-channel voice on/off
  • Charger / inverter centralized management; UPS channel keeps the fridge powered

Sensing & Networking Summary

ItemSpecification
Water levelTANK1–4, 4 channels (6-segment)
TemperatureT1–T2, 2 channels PT100 (-40℃ ~ 100℃)
Tire pressureUp to 6 sensors (433MHz), IP67 / 0–100PSI
CAN ports4 (RJ45, cables included)
Remote upgradeRemote upgrade module (optional)
Specifications

Technical Parameters

Smart PDU Main UnitSpecification
ModelSmart PDU (19-inch standard rack housing)
System voltage12V
Max charge / discharge50A / 70A
Load outputs15 channels: 8×10A + 4×20A + 3×30A (independent control)
Water levelTANK1–4, 4 channels (6-segment)
TemperatureT1–T2, 2 channels PT100 (-40℃ ~ 100℃)
Tire pressureUp to 6 sensors (433MHz)
Display7-inch TFT touch panel (169×122mm flush cutout)
CAN ports4 (RJ45, cables included)
Fuses10A / 20A / 30A blade type, top service port, per-channel status LED
Operating / storage temp-20℃ ~ +60℃ / -40℃ ~ +85℃
Size / weight440 × 150 × 69 mm; main unit 4kg, 7" panel 318g
Warranty1 year from purchase (non-human-induced issues)
Built-In Coulomb MeterSpecification
Voltage8–24V, resolution 0.01V, accuracy ±2%
Current0–50A, resolution 0.01A, accuracy ±5%
Temperature0–100℃
Capacity0–100% display
Power0–72kW, resolution 0.001W
Ah / Wh0–9999.99AH (0.001AH) · 0–9999.99kWh (0.01WH)
Sampling rate1 / second
ProtectionOver/under-voltage, over-current, over-power, over-temp — alerts + buzzer
Smart detectionAuto charge/discharge direction detection; live battery capacity, external source and charger status
Alarm & Protection

Graduated Alarm & Protection Strategy

The system responds by severity: warnings first, safety-critical events cut loads immediately — all visualized on the panel.

ConditionSystem Response
Total output > 80ARed alarm + 7 beeps (~50dB), all loads auto-disconnected
Total output 70–80AYellow alarm + 3 beeps; unacknowledged → yellow warning icon; auto-recovers below 70A
SOC ≤ 5%Battery info area turns red
Water level lowest / sensor missingWater level shown in red
Temperature > 55℃Temperature shown in red
Battery overheatingAll DC load outputs shut off, red alarm + continuous buzzer; auto-recovers when temperature normalizes
Fuse faultPer-channel LED at the service port; replace with same-rated fuse (never increase the rating)
15 ch
Independently controlled DC loads
70A
Max discharge (charge 50A)
1 /s
Coulomb meter sampling rate
80A
Total-output protection cutoff
Standard & Optional

What's in the Box & What's Optional

The main unit and control panel are standard; water-level, tire-pressure and other sensors are optional per vehicle.

StandardContents
Main unit & panelSmart PDU main unit, 7" touchscreen
Temp sensorPT100 temperature sensor (1m cable)
Wiring kitT25-8 lugs, connector pack (10A / 20A / 30A / sensors)
Mounting kitScrew pack, screwdriver
DocumentationUser manual, packaging box
OptionalSpecification
Tire-pressure sensors433MHz, 2.1–3.3V, response <5s, IP67, -30~+70℃, 0–100PSI, 2–3 year battery life
Threaded level sensors150 / 175 / 200mm; BSP1 1/4 steel head, 304 stainless rod, 0–190Ω output, reed-switch sensing, -40~+75℃
Remote upgrade moduleWith dedicated cable, supports remote firmware updates
Fuse boxWith 80A fuse
Spare fuses10A / 20A / 30A / 80A